MES Midlands Electronic Solutions

TECHNICAL DATASHEET
LEDO-DS-001 / Rev 0.1 / 15 Oct 2026

DRAFT - NOT FOR RELEASE. Specifications are transcribed from the product website and require engineering approval. Items marked "Confirm" remain unresolved.

LED_O

Industrial machine-status display

Show operators machine status, alarm messages and live process values. Control a full-colour LED display from a compatible PLC over Modbus TCP, with browser-based configuration.

Clear information at the machine

  • Display text, numeric values and user-defined bitmaps.
  • Configure high and low alarms with selectable colours.
  • Control display content through Modbus holding registers.
  • Commission using the built-in web interface.
  • Power from a standard 24 V DC supply.
LED_O product rendering with pole mount
Pole-mount rendering. Not a dimensioned drawing.
Display, power and communications
DisplayRGB LED array; 32 × 124 pixels
LED / pixel pitchSMD2121 RGB / 3 mm
Colour depth14-bit RGB
Brightness800-1200 cd/m²
Viewing angle / refresh≥140° / ≥1920 Hz
Supply voltage24 V DC ±10%
Current consumption1.1 A stated; Confirm: typical or maximum and test conditions
Power protectionReverse-polarity, over-current and over-voltage
CommunicationsEthernet; Modbus TCP (port 502); HTTPS web interface
Modbus functionsFC03: read holding registers; FC06: write single register; FC16: write multiple registers

PLC must support operation as a compatible Modbus TCP client. Refer to the Programming Manual for register addresses, data formats and control behaviour.

Midlands Electronic Solutions / LED_O / Draft technical datasheet LEDO-DS-001 / Rev 0.1 / 1 of 2
MES LED_O

MECHANICAL / INSTALLATION / ORDERING
DRAFT - NOT FOR RELEASE

Mounting and enclosure

LED_O wall-bracket mounting rendering
Wall-bracket mounting
LED_O wall-bracket mounting detail rendering
Bracket detail
Dimensions (W × H × D)100 × 428.5 × 100 mm; Confirm: applicable mounting assembly
Weight1.25 kg; Confirm: included mounting hardware
EnclosureABS with polycarbonate diffuser
Ingress protectionIP65 - dust-tight and protected against water jets. Not suitable for immersion.
Operating temperature0°C to 60°C

Renderings are illustrative, not to scale. Dimensioned mounting drawings, hole positions and installation clearances must be added before release.

System connection

PLC
Modbus TCP client
Ethernet
Network
LED_O
Display

Provide a separate 24 V DC supply to LED_O. This is a system overview, not a wiring diagram. Follow the Instruction Manual for installation; connector types, power pinout and supply requirements must be verified before wiring.

Ordering and evaluation

Contact Midlands Electronic Solutions to discuss your application, mounting requirements, quantity and sample availability.

Confirm before release: order codes, supplied items, optional accessories, lead time and warranty.

Supporting documentation

Sales: mes@led-o.ddns.net
Stoke-on-Trent, United Kingdom

Engineering approval required

Verify all specifications, environmental limits, mounting drawings and connection details. Confirm compliance markings and applicable standards against the Declaration of Conformity. Confirm the sales contact and replace draft status only after approval.